How to Enable a 7847i to a Vista 20 Panel.

Written By engineerisaac

Posted: Fri, Jan 24, 2020 at 11:17 AM - Showing 363 Views


https://engineerisaac.com/screenshots/JOE-PC_950a05.png

Its actually really simple. But not written down anywhere.

On your panel
https://engineerisaac.com/screenshots/JOE-PC_d99b10.png

Get into programming.
(INSTALLER CODE)800 Default installer code is 4112. So Verbatum you press 4112800 if the installer code is default.
https://engineerisaac.com/screenshots/JOE-PC_179db6.png

Move to The enable IP/GSM Field by pressing *29
https://engineerisaac.com/screenshots/JOE-PC_ba47f0.png

Press 1 to enable the Device.
https://engineerisaac.com/screenshots/JOE-PC_032ad8.png

Press the * to Go Back after you enable.
https://engineerisaac.com/screenshots/JOE-PC_179db6.png

Now press *54
https://engineerisaac.com/screenshots/JOE-PC_389459.png

Its currently set to 54 change it to 1 by pressing 1
https://engineerisaac.com/screenshots/JOE-PC_83a80d.png

press * to go back.
https://engineerisaac.com/screenshots/JOE-PC_179db6.png

Now Press *55 on the keypad.
https://engineerisaac.com/screenshots/JOE-PC_44f9ac.png

Its currently set to 55 change it to 1 by pressing 1
https://engineerisaac.com/screenshots/JOE-PC_70dac4.png

Now press* to Exit out of the mode.
https://engineerisaac.com/screenshots/JOE-PC_179db6.png

Now press Now press*99 to exit your panel and Restart the chip when it returns will start system ready.
https://engineerisaac.com/screenshots/JOE-PC_d99b10.png

Shortly after that you will see This error message about Check 103.
https://engineerisaac.com/screenshots/JOE-PC_9d4220.png

This means that the Device is reporting no monitoring services. This is where you will then proceed to Alarm-net.